15kv 150mm2 xlpe underground steel wire armored power cables single core or three phase

Basic Information
Place of Origin: CHINA
Brand Name: CHINT
Certification: CE/SGS/KEMA
Model Number: LSZH(WDZR-YJY23)
Minimum Order Quantity: Negotiable
Price: Negotiable
Packaging Details: Wooden drum/iorn drum
Supply Ability: 500km/month
Process: Three Layer Co-extruded CCV Producing Line Standard: IEC60502.2 IEC60332-3 Or IEC60754
Armor: Steel Wire Port: Shanghai
Inner Sheath: LSZH Material Rated Voltage: 8.7/15kv
High Light:

lszh power cables

,

flame retardant low smoke cables

15kv 150mm2 xlpe underground steel wire armored power cables single core or three phase
Detailed Product Description
 
Note:
Insulation identification as per standards or customer requirement
Applications
Laying in room ,tunnel ,cable trench ,and pipes.
Standards
International: IEC 60502, IEC 60228, IEC 60332, IEC 60754
China: GB∕T 12706.2-2008, GB∕T 19666-2005
Other standards such as BS,VDE and ICEA upon request
Certificates
CE, SGS, KEMA and more others at request 
 
What is LSOH Power Cable
Typical structure of LSOH flame-retardant cable: non-metallic cable cladding material is LSOH flame-retardant material with different properties. This structure enables the cable to pass class A tests in IEC 60332-3-22 and related tests in IEC 60754 and IEC 61034.
 
Benefits of FR Cable
When a fire occurs, the combustion of combustibles in the ordinary power system will produce a large amount of halogen-containing smoke. The LSOH power cable and the LSOH building materials used together can effectively reduce the total amount of smoke released by combustible combustion and the content of halogen, so as to reduce the casualty rate in the fire.
The cable has better axial tension resistance.
 
Constructions
Conductor : Compact stranded copper conductor, Cl.2 as per IEC 60228
Conductor Screen: Semi-conductor
Insulation : XLPE(cross-linked polyethylene) rated at 90 ℃
Insulation Screen: Semi-conductor
Screen : Copper tape
Interlining: LSOH Flame Retardant Polyolefin, black
Armouring: SWA(Steel Wire Armouring)
Sheath : LSOH Flame Retardant Polyolefin, black
 
Technical data
Rated voltage: 8.7/10 kV
Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.
Min. Ambient Temp.: The cable shall be pre heated if the ambient temperature is below 0℃
Min. Bending Radius: single core cable 20(d+D)±5%
Multi-core cable 15(d+D)±5%
 
Technical Specifications

Nom. Cross-section of conductorStrands No./Dia. Of ConductorInsulation
Thickness
Thickness of Copper StripDiameter of steel wireSheath ThicknessApprox. O.D.Approx.Max. D.C Resistance of Conductor (20 ℃)Testing Voltage A.CCurrent Rating
WeightIn air (A)In soil(A)
1×257/2.17+0.014.50.121.601.828.111020.72735165160
1×357/2.56+0.014.50.121.601.929.312450.52435205190
1×5019/1.86+0.014.50.121.601.930.614220.38735245225
1×7014/2.56+0.014.50.121.602.032.517010.26835305275
1×9519/2.56+0.024.50.122.002.135.121070.19335370330
1×12024/2.56+0.024.50.122.002.136.624080.15335430375
1×15030/2.56+0.014.50.122.002.138.027230.12435490425
1×18537/2.56+0.024.50.122.002.240.031700.099135560480
1×24048/2.58+0.024.50.122.002.342.438240.075435665555
1×30060/2.58+0.024.50.122.002.344.644750.060135765630
1×40060/2.93+0.024.50.122.502.549.556860.04735890725
1×50060/3.33+0.024.50.122.502.653.185430.0366351030825
1×63060/3.76+0.024.50.122.502.756.7101350.0283351200950
3×257/2.17+0.014.50.102.502.654.050280.72735120125
3×357/2.56+0.014.50.102.502.756.455890.52435140155
3×5019/1.86+0.014.50.102.502.860.063180.38735165180
3×7014/2.56+0.014.50.102.502.963.973740.26835210220
3×9519/2.56+0.024.50.102.503.167.985870.19335255265
3×12024/2.56+0.024.50.102.503.271.697130.15335290300
3×15030/2.56+0.014.50.103.153.376.1116930.12435330340
3×18537/2.56+0.024.50.103.153.480.4133710.099135375380
3×24048/2.58+0.024.50.103.153.685.7156870.075435435435
3×30060/2.58+0.024.50.103.153.891.0181550.060135493485
3×40060/2.93+0.024.50.103.154.097.9216570.04735565520
 

 
Ordering Advice
Rated Voltage
Application Standard: IEC/BS/UL/GB
Number of Cores
Conductor Size & Construction
Type of Insulation
Armored or unarmored. If armor, the armor type & material
The Requirement of Sheath
Length of Cable & Packing Requirement
Other Requirement
 
PACKING AND SHIPPING
We are capable of meeting the strictest delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self-adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.
 
Product photo
15kv 150mm2 xlpe underground steel wire armored power cables single core or three phase 0

Contact Details
Tina

Phone Number : +8613456374360

WhatsApp : +8619884314399